The walls of concrete, formwork blocks are not sufficient to guarantee the absence of penetration or leakage of water.
CONSTRAINTS
- the singular points such as sewage, water inlets and windows are weaknesses for sealing
- by construction, a concrete structure has weak links such as wall / slab, porous areas, the construction joints
- the joints between the blocks and the angles are the weaknesses of the structure, which can cause leaks
- when the pool is full, the waterproofing mortar under pressure of the water
- when the pool is empty, the mortar waterproofing against the sudden-pressure due to surrounding terrain
- waterproofing mortar must also be compatible with the coatings used in swimming pool
SUBSTRATE PREPARATION
- the singular points such as windows, inlets and outlets of water ... should be treated in accordance with the technical documents used accessories
- in case of water supply, enlarge the hole infiltration to a minimum area of 3 x 3 cm
- then plug the hole with the mortar clogging weber.dry stop
- to achieve continuity in the waterproofing layer, make a groove in all the corners, using:
- to concrete: weber.rep fast or weber.rep area
- blocks of formwork: weber.rep fast or coated weber.dry
Useful Links:damp proofing